WB5 Fixed Monitoring Alarm System

SG Series Detector Specifications:


CO, H2, NO, NH3, H2S, SO2, NO2, Cl2, HCN, O2, HCl, H2, CXHX%LEL

Enclosure:
Cast aluminum, IP66 rated
Sensors:
Combustible Gases: Catalytic bead and/or Non-Dispersive Oxygen / Toxic Gases: Electrochemical diffusion
Ranges:
Combustible gases: 0 -100% LEL in 1% increments

Hydrogen: 0 - 999 ppm in 1 PPM increments

Oxygen: 0 - 30.0% by volume in 0.1% increments

Ammonia: 0 - 200 PPM in 1 PPM increments

Carbon Monoxide: 0 - 999 PPM in 1 PPM increments

Hydrogen Sulfide: 0 - 500 PPM in 1 PPM increments

Sulfur Dioxide: 0.2 - 99.9 PPM in 0.1 PPM increments

Hydrogen Chloride: 0.2 - 30 PPM in .01 PPM increments

Nitrogen Dioxide: 0.2 - 99.9 PPM in 0.1 PPM increments

Nitric Oxide: 0.0 - 99.9 PPM in 0.1 PPM increments

Chlorine: 0.2 - 99.9 PPM in 0.1 PPM increments
Display:
Dual-channel split-screen LED display
Input Voltage:
12-28 VDC operating range (24 VDC typical)

 

WB5 Monitor:

Channels:
1 or 5,7(can select)

Input Current (max.):
Toxic Gas / Oxygen: Two wire system ,20 mA @ 24 VDC (single gas)Combustible gases (Catalytic): Three wire system, 65 mA @ 24 VDC, (single gas)Combustible gases (Infrared): 190 ma @ 24 VDC(single gas)

Alarm Relays:


2 alarm relays: Two user-programmable relays,

Signal Output:
4-20 mA, RS485

Power:
AC220V 50HZ

Size: 350(W)mm×160(H)mm×300(L)mm

Contact Capacity:
1 Amps @ 220 VAC


Temperature Range:
-20oC to +50oC


Humidity Range:
15-90% RH (non-condensing), typical


Approvals: (sensor-specific)
China: GB 3836.1-Ex d IIC T4; LEL version